Catalog sections
Smartag temperature indicatorsour own product: −30…+70 °C, USB flash storage, PDF report
Smartag minisingle-use, LED indication, 1–2 thresholds
Smartag Treusable temperature indicator, 45,000-value memory
Smartag RHTreusable, temperature and humidity
Smartag TZremote probe 120–500 mm, two points
Smartag Zondprobe for Smartag TZ and I2C monitoring systems
Smartag trackcargo temperature and location in real time- Wired sensorsRS-485 thermohygrometers, sensors with remote probes, pressure, CO₂
- Wireless sensorsLoRa for warehouses and cold rooms, Wi-Fi for pharmacies and laboratories
- Cabinets, UPS and alarmscontrollers, gateways, GSM modules, sirens and displays
- Failure and pressure sensorswater leak, dry contact, 220 V presence, differential pressure
- Particle counterscleanroom classification and monitoring
- Medical equipmentultrasound, diagnostics, furniture, fitting out of treatment rooms
- Smartag data loggersfor mapping and transport
- Choosing temperature indicatorsthe cold chain in transit
- Instrument requirements and verificationhow to check an instrument in FSIS Arshin
What to choose
| Task | Equipment | Why |
|---|---|---|
| Continuous warehouse monitoring | wired RS-485 thermohygrometers + control cabinet | powered over the cable, no batteries, stable communication |
| Monitoring of cold rooms in operation | LoRa wireless sensors with a probe inside the room | no need to run cables through the insulation |
| −80 °C freezer | sensor with a remote Pt100/Pt1000 probe | electronics stay outside the cold |
| Pharmacy, vaccination room | Smartag RHT in rooms and Smartag T in refrigerators, or Wi-Fi sensors of the monitoring system | verified instruments; for 24/7 alarms, a monitoring system |
| Temperature mapping | Smartag T or Smartag RHT of a single type | ±0.5 °C over −30…+40 °C, meets the EEC Guideline requirements |
| Transport in a refrigerated truck | Smartag track or Smartag T | recording throughout the trip and a report for the consignee |
| Insulated containers with vaccines | Smartag mini | LED indication of an excursion at receipt, serial number for the log |
| Liquids, points inside cold rooms | Smartag TZ with Smartag Zond | remote probe in a stainless steel sleeve |
| Cleanrooms | differential pressure sensors , particle counter , display at the entrance | control of the pressure cascade and cleanliness class |
| Early detection of failures | water leak sensor , 220 V monitoring , dry contact | the cause is visible before the temperature drifts |
| Fitting out a medical treatment room | medical equipment and furniture | selection according to the equipment standard of the Ministry of Health order |
General requirements for measuring instruments
| Type | measuring instrument of an approved type, listed in the Federal Information Fund for Ensuring the Uniformity of Measurements |
| Verification | valid, recorded in FSIS Arshin |
| Temperature accuracy | no worse than ±0.5 °C over the operating range (EEC Guideline, SanPiN 3.3686-21) |
| Recording interval | configurable; for vaccines, at least once per minute |
| Documents | data sheet and operating manual in Russian |
| Data | identification of the instrument and period in reports, protection against alteration |