Control Cabinets, UPS and Alarm Devices

The control cabinet is the heart of the site: sensor lines and radio gateways converge here, it houses the controller with its data buffer and the uninterruptible power supply, and the backup communication channel is also connected here. If the site loses power or internet access, the cabinet keeps collecting data and reports the problem.

Monitoring system control cabinet with a controller, UPS, GSM module, gateway and siren
Schematic illustration of a control cabinet and a visual/audible alarm device.

Cabinet components

ComponentPurpose
Data acquisition controllerpolling of RS-485 lines and gateways, buffering of measurements, transmission to the server, local alarm logic
Uninterruptible power supplykeeps the controller, sensors and communications running during a power outage; backup time is calculated for the site
GSM/LTE modulebackup communication channel, SMS and calls when there is no internet
LoRa gatewayreceives data from wireless sensors
Ethernet switchconnection to the corporate network
Terminals and line protectionconnection of sensor lines, surge protection
Discrete signal inputsdoors, refrigeration unit failure, voltage presence
Alarm device control outputsactivation of sirens, beacons and displays on alarm

On-site alarm devices

DeviceWhere to installWhy
Visual and audible alarmnear cold rooms, in the storage area, at the security postalerts staff even when phones are unavailable
LED displayin the dispatch area, near cold roomscurrent values and status without logging into the system
Audible alarm on the operator workstationat the duty officer's desk, in the control roomalarms by group with different sounds and repetition

SanPiN 3.3686-21 requires refrigerated and freezer rooms for vaccines to be equipped with a temperature alarm and requires a backup power supply for the refrigeration equipment and monitoring devices.

Typical specifications

Enclosurewall-mounted metal cabinet, protection rating to suit the installation site
Power~220 V with UPS; backup time as calculated
InterfacesRS-485 (several lines), Ethernet, LoRa, GSM/LTE
Discrete inputs and outputsas per the design
Data bufferstores measurements while the connection to the server is lost
Placementin a heated room, outside the storage area, with access for maintenance

Frequently asked questions

How long does the system run during a power outage?

We calculate the backup time based on the number of sensors and the customer's requirements; the UPS is sized with a margin, and the system reports the power loss immediately.

Does a pharmacy need a cabinet?

For a small Wi-Fi or GSM system a separate cabinet is usually not needed; sensors plus a server or the cloud are enough.

Need mapping or qualification? Send us your floor plan — we will calculate the number of points and the timeline.