Service, Verification and Calibration

A monitoring system proves that products have been kept safe only as long as the sensors are verified, communications work and the archive is intact. We take care of all of this: we manage the verification schedule, swap sensors from our replacement pool without interrupting monitoring, maintain the equipment and respond to technical alarms.

What support includes

TaskFrequencyResult
Verification schedule and remindersongoingno sensor operates with an expired verification
Sensor verificationper the verification interval in the type description (usually 1–3 years)verification record in FSIS Arshin, entry in the maintenance log
Replacement from the pool during verificationat every verificationuninterrupted monitoring and archive
Calibrationon request or per internal procedurecertificate with actual error values, drift assessment
Testing of alarms and notification channelsquarterlyconfirmation that SMS, calls and MAX messages reach recipients
Check of UPS units, GSM modules, wireless sensor batteriesevery six monthscomponents replaced before they fail
Archive and backup checksmonthlyrestore test, integrity report
Periodic review of the validated stateannuallyreport on changes and the need for repeat testing
Software updatesby agreementchange control and regression testing

Verification vs. calibration: what is the difference

Verification confirms that a measuring instrument meets metrological requirements and is mandatory for measurements within the scope of state regulation, which includes monitoring of storage conditions for medicinal products. The result is entered in FSIS Arshin. Calibration determines actual error values and helps assess drift between verifications, especially for humidity sensors.

SanPiN 3.3686-21 requires the supplier or carrier of immunobiological medicinal products to confirm, at the recipient’s request, that verifications are up to date, and the supporting documents must be kept by the person responsible for the cold chain. Under our support service, we prepare this package automatically.

Support levels

The scope and response times are set out in the contract.
BasicExtendedPharma
Verification and replacement poolyesyesyes
Remote supportbusiness hoursextended hours24/7
Engineer site visitson requestscheduled visitsscheduled visits and emergency call-outs
Alarm and archive checks—quarterlymonthly
Periodic review of the validated state——annually
Re-mapping—on requestper risk analysis schedule

Frequently asked questions

How often do sensors need to be verified?

At the verification interval specified in the type description of the measuring instrument: usually 1–2 years for thermohygrometers, and up to 3 years for some sensors.

Is monitoring interrupted during verification?

No. We install sensors from our replacement pool, and the system records the swap with serial numbers.

Can you support a system from another manufacturer?

Yes, if the equipment is documented and accessible for diagnostics. We start with an audit of the system and its documentation.

Need mapping or qualification? Send us your floor plan — we will calculate the number of points and the timeline.